Search Frequent Questions
Filter By:
- Oil Regulations Total results: 96
- Air Emissions Inventories Total results: 34
- Asbestos Total results: 141
- Butte Area/Silver Bow Creek Total results: 17
- Coronavirus (COVID-19) Total results: 33
- East Palestine, Ohio Train Derailment Total results: 148
- Emergency Planning and Community Right-to-Know Total results: 301
- Fuel Program Total results: 693
- Great Lakes Funding Total results: 92
- Lead Total results: 401
- MOVES Total results: 57
- Norwood Landfill Site Total results: 30
- Permitting Under the Clean Air Act Total results: 19
- Radiation Total results: 1
-
Risk Management Program (RMP)
Total results: 285
- Applicability/General Duty Clause Total results: 69
- Emergency Response Total results: 6
- Five-Year Accident History Total results: 16
- Offsite Consequence Analysis (OCA) Total results: 57
- Other Risk Management Programs Total results: 35
- Plan Preparation and Submission Total results: 49
- Prevention Program Total results: 30
- Program Levels Total results: 16
- RMP*Comp Total results: 7
- Southeast Minnesota Groundwater Total results: 11
Displaying 121 - 135 of 165 results
-
SPCC Qualified Facilities Substantial Harm Criteria Certification
Are SPCC qualified facilities required to complete and maintain a copy of the Certification of the Applicability of the Substantial Harm Criteria form located in Appendix C of 40 CFR Part 112? Yes, all SPCC regulated facilities, including qualified facilities, that do not meet the criteria of a substantial harm…
- Last published:
-
FRP Site Plans with Varying Storage Contents
The Facility Response Plan regulations require subject facilities to prepare and maintain a site plan diagram that includes, among other things, the contents of bulk oil storage tanks, drum oil storage areas, and surface impoundments ( 40 CFR Part 112 Appendix F ). When the contents of these storage units…
- Last published:
-
SPCC Training Materials for Production Sector
Does EPA offer any Spill Prevention, Control, and Countermeasure (SPCC) training materials specifically for the production sector? Yes. EPA has developed a “train-the-trainer” presentation for the production sector. The presentation provides information for organizations to hold trainings on the SPCC rule. The presentation is available in the SPCC Rule: Train-the-Trainer…
- Last published:
-
What milk and milk products are covered by the Milk and Milk Product Containers, Associated Piping and Appurtenances Exemption?
The exemption will cover all containers, piping and appurtenances of milk and milk products. For example, milk products include cheeses, yogurts and ice cream. Additionally, transfers and milk handling associated with these containers and appurtenances are exempt from the SPCC requirements.
- Last published:
-
How did EPA select the list of regulated substances?
The list of regulated substances under the chemical accident prevention provisions is found in 40 CFR Part 68. How did EPA select the substances to be included in this list? The chemical accident prevention provisions promulgated pursuant to Section 112(r) of the Clean Air Act (CAA) are designed to focus…
- Last published:
-
RMP Contractor Related Requirements
Facilities subject to the Program 3 Prevention Program requirements in 40 CFR Part 68 must include in their Risk Management Plan the date of the most recent review or revision of contractor safety procedures in Section 7.14 and the date of the most recent review or revision of contractor safety…
- Last published:
-
Distinction between "process" and "covered process"
What is the distinction between a "process" and a "covered process" under the risk management program regulations at 40 CFR Part 68? Process means any activity involving a regulated substance, including any use, storage, manufacturing, handling, or on-site movement of such substances, or combination of these activities. A "covered process"…
- Last published:
-
Threshold determination for mixture containing flammable substance and water
A stationary source has in a process a mixture containing 9,000 pounds of butane and 1,001 pounds of water. The mixture meets the criteria for a National Fire Protection Association flammability rating of 4 (NFPA 4). Is this process covered under the RMP regulations? Yes. Where the concentration of the…
- Last published:
-
What is the definition of fuel for the purposes of the fuel exclusion for the risk management program?
A flammable substance listed in 40 CFR §68.130 is excluded from the risk management program regulations when it is used as a fuel or held for sale as a fuel at a retail facility (§68.126). What is the definition of fuel for the purposes of this exclusion? The two prongs…
- Last published:
-
Why did EPA select the twenty percent concentration cut-off value for aqueous ammonia?
The list of regulated substances in 40 CFR §68.130 includes aqueous ammonia that is at a concentration of 20 percent (by weight) or greater. Why did EPA select 20 percent as the concentration cut-off value? Commonly used commodity solutions of ammonia (which mean the bulk shipments, not bottles of ammonia…
- Last published:
-
Stationary source subject to OSHA PSM but below EPA threshold
A stationary source is subject to the OSHA process safety management standard (PSM) because it exceeds the OSHA PSM threshold for chlorine. The stationary source does not, however, exceed the threshold for chlorine (or any other regulated substances) in a process under the Risk Management Program regulations (40 CFR §68.130)…
- Last published:
-
Can a containment wall be constructed out of concrete blocks?
Yes. SPCC regulations do not mandate design specifications, rather, they are performance based. Therefore, a containment wall may be of any construction type, material, or design, assuming it meets the performance standards and requirements of Part 112. Regional offices can help determine whether individual containment equipment meets the performance standards…
- Last published:
-
Qualifying criterion for qualified oil-filled operational equipment
What is the qualifying criterion for the option for qualified oil-filled operational equipment? Equipment is eligible if the facility did not discharge from any oil-filled operational equipment (1) more than 1,000 U.S. gallons of oil in a single discharge to navigable waters, or (2) discharge more than 42 U.S. gallons…
- Last published:
-
For SPCC training purposes, who is considered oil-handling personnel?
Pursuant to 112.7(f)(1), the owner or operator of a facility subject to the SPCC regulations must train oil-handling personnel in the operation and maintenance of equipment, discharge procedure protocols, applicable pollution control laws, rules and regulations, general facility operations and the contents of the facility SPCC Plan. For the purposes…
- Last published:
-
Tier I qualified facility template use under Part 112
In the 2008 Amendments to the SPCC Rule, EPA provided a template for the owner or operator of a Tier I qualified facility to create an SPCC Plan. Does EPA require a Tier I qualified facility to use the template in 40 CFR Part 112, Appendix G? Does EPA allow…
- Last published: