Search Frequent Questions
Filter By:
-
Risk Management Program (RMP)
Total results: 285
- Applicability/General Duty Clause Total results: 69
- Emergency Response Total results: 6
- Five-Year Accident History Total results: 16
- Offsite Consequence Analysis (OCA) Total results: 57
- Other Risk Management Programs Total results: 35
- Plan Preparation and Submission Total results: 49
- Prevention Program Total results: 30
- Program Levels Total results: 16
- RMP*Comp Total results: 7
- Air Emissions Inventories Total results: 34
- Asbestos Total results: 141
- Butte Area/Silver Bow Creek Total results: 17
- Coronavirus (COVID-19) Total results: 33
- East Palestine, Ohio Train Derailment Total results: 148
- Emergency Planning and Community Right-to-Know Total results: 301
- Fuel Program Total results: 693
- Great Lakes Funding Total results: 49
- Lead Total results: 401
- MOVES Total results: 57
- Norwood Landfill Site Total results: 30
- Oil Regulations Total results: 96
- Permitting Under the Clean Air Act Total results: 13
- Radiation Total results: 1
- Southeast Minnesota Groundwater Total results: 11
Displaying 196 - 210 of 286 results
-
Difference between RMP update and RMP correction
What is the difference between an update and a correction to a risk management plan (RMP)? Updates and resubmissions require the owner or operator to review and revise all sections of the RMP as needed to bring the RMP up to date and the submission must be accompanied by a…
- Last published:
-
Can a newly-constructed process that has no accident history qualify for Program 1 status?
The eligibility criteria for Program 1 status under 40 CFR Part 68 include a requirement that the process must not have had an accidental release resulting in serious offsite consequences for the past five years (40 CFR §68.10(b)(1)). Can a newly-constructed process that has no accident history qualify for Program…
- Last published:
-
After a reportable accident, do I have to revise my RMP?
I recently submitted my five-year RMP update required by section 68.190 (b)(1) and included my accident history for the previous five years. Two months later, we had another reportable accident. Do I have to do anything to revise my RMP? Yes. You must revise your accident history within six months…
- Last published:
-
Does EPA confirm receipt of a facility's RMP?
A facility subject to the risk management program regulations must submit its risk management plan (RMP) to EPA via the RMP*eSubmit system. Does EPA confirm receipt of the facility's RMP? When a facility's certifying official submits a complete RMP to EPA using RMP*eSubmit, the system will automatically generate and send…
- Last published:
-
Five-year accident history in initial RMP submission
The owner or operator of a stationary source subject to 40 CFR Part 68 must include a five-year accident history that includes significant accidental releases of one or more of the regulated substances from a covered process in the five years prior to the submission of an initial or updated…
- Last published:
-
Are processes subject to delegated state OSHA programs classified as program level 3?
If my state administers the OSHA program under a delegation from the federal OSHA, does that mean that my processes that are subject to OSHA PSM under the state rules are in Program 3? Yes, as long as the process does not qualify for Program 1. Any process subject to…
- Last published:
-
Is EPA's PHA stationary source siting requirement analogous to OSHA's PSM?
Does EPA interpret the Program 3 process hazard analysis - stationary source siting requirement analogously to OSHA's Process Safety Management standard? Yes. The requirement to consider stationary source siting during the process hazard analysis means that you should consider the location of the covered vessels and evaluate whether their location…
- Last published:
-
What do I have to do for material and energy balances?
For new processes, you must document both material and energy inputs and outputs of a process. For example, you would document the quantity of a regulated substance added to the process, the quantity consumed during the process, and the quantity that remains in the output. This requirement will not generally…
- Last published:
-
Worst case release scenario for toxic and flammable substances in same Program 1 process
Under the risk management program regulations in 40 CFR Part 68, if a Program 1 process contains a threshold amount of both a regulated toxic substance and a regulated flammable substance, should a worst case release scenario be analyzed for each of the substances in the process? Yes, a worst…
- Last published:
-
Definition of off-site for identifying public receptors
My processes are fenced, but my offices and parking lot for customers are not restricted. What is considered offsite? What is considered a public receptor? The unrestricted areas would be considered offsite. However, they would not be public receptors because you are responsible for the safety of those who work…
- Last published:
-
What measures qualify as "passive mitigation"?
Passive mitigation is defined in § 68.3 as "equipment, devices, or technologies that function without human, mechanical, or other energy input." Passive mitigation systems include building enclosures, dikes, and containment walls. Measures such as fire sprinkler systems, water curtains, valves, scrubbers, or flares would not be considered passive mitigation because…
- Last published:
-
Are all covered processes subject to identical risk management program requirements?
The risk management program regulations in 40 CFR Part 68 are applicable to owners or operators of stationary sources at which more than a threshold quantity of a regulated substance is present in a process (40 CFR Section 68.10(a)). Are all covered processes subject to identical risk management program requirements…
- Last published:
-
What is the definition of a "technically qualified individual"?
For the purpose of determining whether more than a threshold amount of a regulated substance is present at a stationary source under 40 CFR Part 68, certain exemptions may apply. One exemption is for regulated substances that are "manufactured, processed, or used in a laboratory at a stationary source under…
- Last published:
-
Remote coordination with local authorities
The Risk Management Program regulations require owners and operators of stationary sources to coordinate their response needs annually, or more frequently if necessary, with local emergency planning and response organizations (40 CFR §68.93(a)). If a stationary source is in a remote location and in-person annual coordination is deemed impractical, can…
- Last published:
-
Certifying RMP process at higher program level
If a process qualifies as Program Level 1, can a facility designate it as a Program Level 2 or 3 in their Risk Management Plan? No. The owner or operator of a stationary source with a process eligible for Program 1 must certify their Program 1 designation in their Risk…
- Last published: